Guide to setup MTX-15 Ethernet Connection



MTX-15 Ethernet Terminal Connection with Time Guardian (TG) v5.0 procedure

  1. Set the ip, using the dgdscvr utility ping test
  2. Then on time guardian, go to Edit > setup
  3. Clock > yes, yes, no, yes
  4. Click on location terminal
  5. Click garbage if says fpt
  6. Go to connection tab, ethernet
  7. Enter the ip
  8. Verify port 2101
  9. Next tab, terminal
  10. Press the magnifying glass
  11. Once serial shows, double click
  12. Change validation to default
  13. Verify active is checked
  14. Click green check mark
  15. Press green check again
  16. Press green check again
  17. Go to communications
  18. Highlight mtx
  19. 4 green buttons on bottom right
  20. Press 2nd from left, this will set time - to test communication

 

 

Note: If this procedure fails, tcp port 2101 may be blocked by the firewall

 

 
 
 

 

 

 

 

 

 

 

 

 

 

 

 