<?xml version="1.0"?>

<rss version="2.0">


<channel>
<title>Home - All Categories - Time Software/Systems  - TruTime  </title>
<link>http://tkb.amano.com/category.php?id=149</link>
<description>This RSS Feed contains Articles of Category in the knowledge base. You can click on the title to view its content. Powered by PHPKB (https://www.knowledgebase-script.com)</description>
<item>
										<guid>http://tkb.amano.com/article.php?id=376</guid>
										<title>Customer service</title>
										<link>http://tkb.amano.com/article.php?id=376</link>
										<description><![CDATA[                           Customer service can be reached via:                                                           Amano Time Unit                                                              Technical Support                                  ...]]></description>

									</item>
<item>
										<guid>http://tkb.amano.com/article.php?id=332</guid>
										<title>Lost Password</title>
										<link>http://tkb.amano.com/article.php?id=332</link>
										<description><![CDATA[          If you&rsquo;ve lost or forgotten your password, fax a request to 1-973-226-7863 or email&nbsp;tgsupport &nbsp; &nbsp;@ &nbsp; amano &nbsp; . &nbsp; com&nbsp;/ ttsupport &nbsp; &nbsp; @ &nbsp; &nbsp; &nbsp; &nbsp;amano &nbsp; . &nbsp; &nbsp...]]></description>

									</item>
<item>
										<guid>http://tkb.amano.com/article.php?id=464</guid>
										<title>Clearing Corruption out of Den tables in Time Guardian that was converted from Trutime</title>
										<link>http://tkb.amano.com/article.php?id=464</link>
										<description><![CDATA[       Sometimes the Densummary and Denormalized_table1 will become corrupt beyond repair. So you will from time to time need to clear them out. For customers who started from scratch in Time Guardian this is a simple delete command.&nbsp;    First r...]]></description>

									</item>
<item>
										<guid>http://tkb.amano.com/article.php?id=370</guid>
										<title>Time guardian installation disc CD</title>
										<link>http://tkb.amano.com/article.php?id=370</link>
										<description><![CDATA[      How to get a copy of the Time Guardian installation disc/CD          With a valid support contract, we can provide a download link. Please contact support:                          Amano Time Unit                        Technical Support       ...]]></description>

									</item>
<item>
										<guid>http://tkb.amano.com/article.php?id=497</guid>
										<title>Record manager inactive error</title>
										<link>http://tkb.amano.com/article.php?id=497</link>
										<description><![CDATA[   Record manager inactive error        fix:        full rights to apps folder        or        open trutime utility &gt; reset # of client &gt; 6569    
]]></description>

									</item>
<item>
										<guid>http://tkb.amano.com/article.php?id=459</guid>
										<title>Recovering Punches from aupoll.bak in Trutime</title>
										<link>http://tkb.amano.com/article.php?id=459</link>
										<description><![CDATA[             Whenever a clock is successfully polled Trutime will copy the punches to two files aupoll.bak and aupoll.dat. Sometimes Trutime will lock up or not process the punches into Trutime. This can be corrected by going into the apps rutime dir...]]></description>

									</item>
<item>
										<guid>http://tkb.amano.com/article.php?id=422</guid>
										<title>Time Guardian &amp; Trutime Daylight Saving setup for various versions</title>
										<link>http://tkb.amano.com/article.php?id=422</link>
										<description><![CDATA[        The links and attachments entails how to setup daylight savings for various clocks in various Time Guardian versions and Trutime. It may not include instructions for all clocks but similar methods can be applied like the various steps mention...]]></description>

									</item>
<item>
										<guid>http://tkb.amano.com/article.php?id=460</guid>
										<title>Hand Punch not bringing in punches in Trutime</title>
										<link>http://tkb.amano.com/article.php?id=460</link>
										<description><![CDATA[        After my Hand Punch was reset punches are not coming into Trutime.        Trutime loaded specific Menu information into HP2000, 3000, 4000. If one of these models are reset intentionally or&nbsp;unintentionally. Then the Menu file needs to be...]]></description>

									</item>
<item>
										<guid>http://tkb.amano.com/article.php?id=472</guid>
										<title>I/O Error (General)</title>
										<link>http://tkb.amano.com/article.php?id=472</link>
										<description><![CDATA[    Some I/O errors are caused by the server not unlocking files. When someone opens an area in Trutime the client pc request exclusive access to certain tables. It creates a file of the same name with the extension LCK.    Example: f_dpunch.lck    O...]]></description>

									</item>
<item>
										<guid>http://tkb.amano.com/article.php?id=467</guid>
										<title>What Time clocks will Trutime operate with:</title>
										<link>http://tkb.amano.com/article.php?id=467</link>
										<description><![CDATA[    What Terminals will work with Trutime:    MTX 10/20 HP1000 HP2000 HP3000 HP4000    What terminals will Trutime not operate with:    MTX 15 FPT 40 All future terminal models
]]></description>

									</item>
<item>
										<guid>http://tkb.amano.com/article.php?id=471</guid>
										<title>GPF while Calculating Time card in Trutime</title>
										<link>http://tkb.amano.com/article.php?id=471</link>
										<description><![CDATA[    This error happens sometimes when a customer is using Advanced Zones and they are not fully configured.    Advanced Zones require 3 days of schedule coverage. You have to configure a day worth of punching prior, the day of, and the day after. The...]]></description>

									</item>
<item>
										<guid>http://tkb.amano.com/article.php?id=73</guid>
										<title>How to update IP settings for the Hand Punch unit and in TruTime</title>
										<link>http://tkb.amano.com/article.php?id=73</link>
										<description><![CDATA[           Below are steps on how to update time for the Hand Punch unit in the Trutime software              Simply access the HP as a supervisor using the clear + enter keys together       Use password 2       Select set serial       When prompted ...]]></description>

									</item>
<item>
										<guid>http://tkb.amano.com/article.php?id=465</guid>
										<title>I/O error on F_Dpunch.btr</title>
										<link>http://tkb.amano.com/article.php?id=465</link>
										<description><![CDATA[       Just after polling, or while going into Edit Daily Data, the user gets "I/O error" on the file F_Dpunch.btr.&nbsp;    This error is related to corruption in the main files that Trutime uses to store and process employee time history.    THIS I...]]></description>

									</item>
<item>
										<guid>http://tkb.amano.com/article.php?id=388</guid>
										<title>TruTime: To restore templates on a repaired handpunch</title>
										<link>http://tkb.amano.com/article.php?id=388</link>
										<description><![CDATA[ TruTime: To restore templates on a repaired handpunch             &nbsp;      1.&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;           With the loaner clock that has been working, perform a receive maps 1 last time         2.&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&n...]]></description>

									</item>
<item>
										<guid>http://tkb.amano.com/article.php?id=462</guid>
										<title>Hard Coded Network Limit</title>
										<link>http://tkb.amano.com/article.php?id=462</link>
										<description><![CDATA[ While trying to log in to Trutime you&nbsp;receive&nbsp;Hard Coded Network Limit error. This error is caused by having more than one client try to log in to Trutime with a Single User License. In order to reset this you need to have the Trutime Util...]]></description>

									</item>
<item>
										<guid>http://tkb.amano.com/article.php?id=466</guid>
										<title>TruTime Compatibility</title>
										<link>http://tkb.amano.com/article.php?id=466</link>
										<description><![CDATA[       Windows Operating Systems that Trutime is&nbsp;compatible with:    Windows XP&nbsp; Windows Server 2000 Windows Server 2003&nbsp;    Operating systems that Trutime has not been tested on and not approved for are:    Windows Vista Windows 7 All...]]></description>

									</item>
<item>
										<guid>http://tkb.amano.com/article.php?id=346</guid>
										<title>Setup scheduled polling and downloading</title>
										<link>http://tkb.amano.com/article.php?id=346</link>
										<description><![CDATA[              1.&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;                       Communications &gt; non-aci                     2.&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;                       File &gt; polling/download schedule                     3.&nbsp;&n...]]></description>

									</item>
<item>
										<guid>http://tkb.amano.com/article.php?id=461</guid>
										<title>F_Mikey Error</title>
										<link>http://tkb.amano.com/article.php?id=461</link>
										<description><![CDATA[ When I try to log into Trutime I get the error f_mikey error, followed by a succession of other errors. the f_mikey.btr in the main apps rutime directory is directly linked with checking a users rights to the Trutime directory and its files.&nbsp; S...]]></description>

									</item>

</channel>

</rss>